JIS cryogenic gate valve

Short Description:

When the low temperature gate valve is closed, the sealing surface can be sealed only by the medium pressure, that is, the sealing surface of the gate is pressed to the valve seat on the other side to ensure the sealing of the sealing surface, which is self sealing. Most gate valves are forced to seal, that is to rely on external force to force the gate to the valve seat to ensure the sealing of the sealing surface


Product Detail

FAQ

Product Tags

DN: 1/2”-2”
PN: PN1.0MPa/PN1.6MPa/10K/16K
Connection type: Female thread (“G”, “NPT”)
Operation: Hand wheel
Body: CF8
Medium: Liquid Ammonia, Liquid Nitrogen, water, gas, oil, Acid-base liquid
Temperature: -196℃≤T≤150℃
Standard: JB/T7746-2006
Face to face: JB/T7746-2006
Threaded End: GB/T7306
Testing and inspection: GB/T13927 API

Advantage:

The fluid resistance is small, the sealing surface by the medium of heavy brush and erosion is small.
It is easier to close and open.
The flow direction of the medium is not limited, the flow is not disturbed and the pressure is not reduced.
The utility model has the advantages of simple shape, short structure length, good manufacturing technology and wide application range.
The disadvantages of low temperature gate valve are as follows:
It is easy to cause erosion and abrasion between the sealing surfaces, which is difficult to maintain.
The opening time is longer and the opening space is longer.
The structure is complex.
According to the sealing surface configuration, gate width can be divided into wedge gate valve and parallel gate valve. Wedge gate valve can be divided into single gate pole type, double gate plate type and elastic gate type; parallel gate valve can be divided into single gate plate and double gate plate type. According to the thread position of the valve stem, it can be divided into two types: rising stem gate valve and Non rising stem gate valve.
The installation and maintenance of low temperature gate valve should pay attention to the following matters:
Handwheel, handle and transmission mechanism are not allowed to be used for lifting, and collision is strictly prohibited.
The double gate valve should be installed vertically (i.e. the stem is in the vertical position and the hand wheel is at the top).
The gate valve with bypass valve should be opened before opening (to balance the pressure difference between inlet and outlet and reduce the opening force).
The gate valve with transmission mechanism shall be installed according to the provisions of the product operation manual.
If the valve is used frequently, lubricate it at least once a month.